Spoon Tip Fat Transfer Cannula – Precision Cannula for Fat Grafting Procedures
$19.00 – $29.00Price range: $19.00 through $29.00
Fat transfer is a widely used technique for restoring volume, enhancing facial contours, and improving soft-tissue depressions caused by aging, scarring, or volume loss. The Laiza Instruments Spoon Tip Fat Transfer Cannula is designed for controlled and precise delivery of harvested adipose tissue during fat grafting, fat transfer, and lipofilling procedures.
Our spoon tip fat transfer cannulas are engineered with a specialized spoon-shaped distal tip to support smooth and controlled placement of fat during delicate aesthetic and reconstructive procedures. The unique tip design allows surgeons to manipulate and distribute prepared adipose tissue with precision, helping achieve consistent results in different fat grafting applications.
Manufactured from premium polished surgical-grade stainless steel, these cannulas provide a smooth internal and external surface to support consistent fat flow and comfortable tissue passage. The durable construction offers excellent strength, corrosion resistance, and reliable performance during professional surgical use.
Spoon Tip Fat Injection Cannula – Precision Cannula for Fat Grafting Procedures
The Laiza Instruments Spoon Tip Fat Injection Cannula is a high-performance surgical instrument specifically developed for surgeons who require specialized tip geometry for advanced fat transfer, fat grafting, and lipofilling techniques.
The unique spoon-shaped distal end provides a specialized configuration for controlled fat placement during injection procedures. Its rounded spoon-like design supports controlled tissue manipulation and precise delivery of prepared adipose tissue into the desired anatomical area.
This specialized configuration is designed to assist with controlled placement of fat in structured layers, which is important when performing procedures requiring accurate volume restoration and smooth contour enhancement. The spoon-shaped tip allows surgeons to work with controlled movements during delicate aesthetic and reconstructive procedures.
The cannula is suitable for facial rejuvenation, soft-tissue volume restoration, correction of depressions, facial contouring, and other fat grafting procedures where precision and controlled tissue handling are required.
Why Surgeons Choose Laiza Instruments
Surgeons choose the Laiza Instruments Spoon Tip Fat Injection Cannula because of its specialized spoon-shaped tip geometry and precision-focused design.
Unlike conventional straight cannulas, the spoon tip configuration provides a unique working surface that supports controlled tissue manipulation and fat placement. The rounded tip is designed to glide smoothly through the tissue while supporting controlled movement during the injection process.
The Blunt Spoon Tip Injector is manufactured with a smooth, polished finish to help reduce unnecessary resistance during use. The specialized tip design provides surgeons with controlled handling and tactile feedback during fat injection procedures.
Manufactured from premium surgical-grade stainless steel, the cannula is designed for durability, strength, corrosion resistance, and reliable performance during professional surgical use. The robust construction helps maintain the integrity of the specialized spoon shape during repeated use and sterilization according to applicable medical facility protocols.
Size Chart & Availability
Laiza Instruments offers a comprehensive range of diameters and lengths to accommodate different anatomical areas and procedural requirements.
| Diameter / Gauge | Available Lengths |
|---|---|
| 0.9mm (20G) | 7cm |
| 1.0mm (19G) | 5cm, 10cm, 15cm |
| 1.4mm (17G) | 10cm, 15cm, 20cm |
| 1.6mm (16G) | 15cm, 20cm, 25cm |
| 2.0mm (12G) | 10cm, 15cm, 20cm |
| 2.5mm (10G) | 10cm, 15cm, 20cm, 25cm |
Technical Details
| Specification | Details |
|---|---|
| Product Name | Spoon Tip Fat Injection Cannula |
| Alternative Name | Spoon Shape Fat Injection Cannula |
| Instrument Type | Fat Transfer / Fat Grafting Cannula |
| Tip Shape | Spoon-Shaped Tip |
| Port Configuration | Single Hole in Spoon Recess |
| Tip Profile | Blunt and Rounded |
| Hub Type | Universal Luer-Lock Hub |
| Hub Options | Super Luer Lock / Steel Hub |
| Material | Premium Surgical-Grade Stainless Steel / Aluminium Options |
| Surface Finish | Mirror-Polished Shaft / Satin Hub / Color-Coated Hub Options |
| Available Diameters | 0.9mm to 2.5mm |
| Available Lengths | 5cm to 25cm |
| Sterilization | Autoclavable and Reusable |
| Application | Fat Grafting, Fat Transfer & Lipofilling |
Clinical Applications & Key Features
The Laiza Instruments Spoon Tip Fat Injection Cannula is engineered to support controlled fat placement and tissue augmentation during aesthetic and reconstructive procedures.
Spoon Tip Geometry
The specialized spoon-shaped distal end is designed to support controlled fat placement and tissue manipulation during injection procedures.
Blunt Spoon Injector
The rounded, blunt tip is designed for controlled tissue passage and helps minimize unnecessary tissue trauma during use.
Controlled Fat Placement
The spoon-shaped configuration supports controlled delivery and placement of properly prepared adipose tissue during fat grafting procedures.
Uniform Fat Layering
The cannula is designed to support consistent and controlled placement of fat during procedures requiring smooth volume restoration and contour enhancement.
Facial Rejuvenation
Suitable for procedures involving facial volume restoration and contour enhancement, including areas such as the cheeks, temples, and other selected facial regions according to the surgeon's technique.
Soft-Tissue Volume Restoration
The cannula can be used for controlled placement of fat in areas requiring restoration of soft-tissue volume.
High-Grade Material
Manufactured from premium surgical-grade stainless steel, providing excellent durability, strength, corrosion resistance, and long-term professional use.
Luer-Lock Compatibility
The universal Luer-Lock connection provides secure attachment to compatible syringes used during fat injection procedures.
Smooth Surface
The polished shaft and smooth internal surface support controlled movement and help reduce tissue adherence during cleaning and reprocessing.
Reusable Design
The cannula is designed for repeated use and sterilization according to applicable medical facility protocols.
Clinical Applications
The Spoon Tip Fat Injection Cannula is suitable for:
- Facial Fat Grafting
- Fat Transfer Procedures
- Lipofilling
- Facial Rejuvenation
- Facial Contouring
- Soft-Tissue Volume Restoration
- Correction of Soft-Tissue Depressions
- Cheek Volume Enhancement
- Temple Volume Restoration
- Body Contouring
- Aesthetic Plastic Surgery
- Reconstructive Surgery
Frequently Asked Questions
Q: What is the advantage of the spoon-shaped tip?
A: The spoon-shaped tip provides a specialized working surface designed to support controlled tissue manipulation and precise placement of prepared adipose tissue during fat grafting procedures.
Q: Is the Spoon Tip Fat Injection Cannula suitable for facial fat grafting?
A: Yes. It is suitable for facial fat grafting, lipofilling, facial contouring, soft-tissue volume restoration, and other aesthetic and reconstructive procedures.
Q: Does the cannula have a blunt tip?
A: Yes. The spoon-shaped distal end features a rounded, blunt profile designed for controlled tissue passage and precise fat placement.
Q: What connection does the cannula use?
A: The cannula is available with a universal Luer-Lock connection, providing secure attachment to compatible syringes.
Q: Is the cannula reusable?
A: Yes. It is manufactured from durable surgical-grade materials and is designed for repeated use and sterilization according to applicable medical facility protocols.
Q: Can this cannula be used for fat harvesting?
A: No. This is a dedicated Spoon Tip Fat Injection Cannula designed for fat injection and lipofilling procedures. Fat harvesting requires a dedicated harvesting cannula with an appropriate port and tip configuration.
SHIPPING & DELIVERY POLICY
1. Order Processing & Shipping Time
In-Stock Products
All in-stock orders are processed and dispatched within 3–4 business days after payment confirmation.
Custom-Made & Backordered Products
Products requiring manufacturing, customization, or currently out of stock may require a production lead time of 10–15 business days before shipment.
Inventory Support Program
For our valued distributors, wholesalers, and repeat customers, Laiza Instruments offers inventory management solutions. We can maintain dedicated stock for customers to ensure faster order fulfillment and reduced delivery times.
2. Delivery Estimates
Laiza Instruments partners with trusted international courier services, including DHL, FedEx, and UPS, to provide secure and timely worldwide delivery.
Estimated Transit Times
USA & North America: 3–5 Business Days
Europe & United Kingdom: 4–6 Business Days
Middle East & Asia: 4–7 Business Days
Rest of the World: 5–7 Business Days
For large-volume orders, we also offer Air Cargo and Sea Freight shipping options upon customer request.
3. Customs Duties & Import Taxes
International customers are responsible for all customs duties, import taxes, VAT, brokerage fees, and any other charges imposed by their local customs authorities.
Please note:
Laiza Instruments is not responsible for customs duties, taxes, or import-related charges.
Laiza Instruments is not liable for shipment delays resulting from customs inspections or clearance procedures.
4. Lost Shipments & Insurance Claims
Although shipping issues are rare, packages may occasionally be delayed or lost while in transit.
Delayed Shipments
If your shipment has not arrived within the estimated delivery period, please contact your local courier office first to determine whether the package is being held for customs clearance or delivery processing.
Lost Shipments
If the courier confirms that the package has been lost, please contact our Customer Support Team immediately. We will assist you with the insurance claim process and arrange a replacement shipment where applicable.
Claim Deadline
All claims regarding lost shipments must be submitted within 21 days (3 weeks) from the expected delivery date.
Claims submitted after this period may not be eligible for insurance coverage, and Laiza Instruments will not be responsible for replacement or compensation.

Reviews
There are no reviews yet.